How to set up MSH-RD080PTW/M7-RD550PTWS pan and tilt values?
Step 1 COM Setting.
- Click Camera Setup ‘Setting’ button on the web system main page, go to ‘COM Settings’ page.

- Set COM parameters for your PTZ camera device.
- COM: 2
- Stop: 1
- Data bits: 8
- Parity: None
- Bits per second: 9600 - Click ‘Apply’ to save the current settings.
- Click ‘Return to the web system main page.
Step 2 PTZ Control Setting.
- Click Surveillance Setup ‘Setting’ button, go to ‘PTZ Control’ page.

- Set PTZ Address, COM Port and Protocol.
- Address: 01
- COM: 2
- Protocol: P_D - Click ‘Apply’ to save the current setting.
- Click ‘Return’, to go back to the web system main page.